Telemetry Point |
Low |
Low |
Nominal |
High |
High |
Units |
Comments |
+5V Digital |
4.8 |
4.9 |
4.998 |
5.1 |
5.2 |
V |
|
+5V Analog |
4.8 |
4.9 |
4.998 |
5.1 |
5.2 |
V |
|
-5V Analog |
-5.2 |
-5.1 |
-4.988 |
-4.9 |
-4.8 |
V |
|
Detector 1 Bias Current |
|
|
0.007 |
0.25 |
0.50 |
uA |
Currents at 20C |
Detector 3 Bias Current |
|
|
0.007 |
0.25 |
0.50 |
uA |
|
Detector 5 Bias Current |
|
|
0.036 |
0.25 |
0.50 |
uA |
|
Detector 2 Bias Current |
|
|
0.21 |
1.25 |
2.50 |
uA |
|
Detector 4 Bias Current |
|
|
0.20 |
1.25 |
2.50 |
uA |
|
Detector 6 Bias Current |
|
|
0.16 |
1.25 |
2.50 |
uA |
|
Thin Detector Bias Voltage Monitor |
1.0 |
2.0 |
2.5 |
3.0 |
4.0 |
V |
HV Bias Off |
Thin Detector Bias Voltage Monitor |
65.0 |
70.0 |
74.2 |
80.0 |
85.0 |
V |
HV Bias On |
Thick Detector Bias Voltage Monitor |
1.0 |
2.0 |
2.5 |
3.0 |
4.0 |
V |
HV Bias Off |
Thick Detector Bias Voltage Monitor |
205.0 |
210.0 |
217.5 |
225.0 |
230.0 |
V |
HV Bias On |
Electrical Cal Amplitude Monitor |
|
|
|
|
|
|
|
Thin Detector LLD Voltage Monitor |
|
|
|
|
|
|
|
Thick Detector LLD Voltage Monitor |
|
|
|
|
|
|
|
Telescope Temperature |
-40.0 |
-30.0 |
-20.0 |
25.0 |
40.0 |
¡C |
Analog Board Temperature |
-40.0 |
-30.0 |
-15.0 |
30.0 |
45.0 |
¡C |
|
Digital Board Temperature |
-40.0 |
-30.0 |
-8.0 |
40.0 |
55.0 |
¡C |
Power Supply Temperature |
-40.0 |
-30.0 |
-15.0 |
35.0 |
50.0 |
¡C |
|
Bulkhead Reference Temperature |
-40.0 |
-30.0 |
-20.0 |
25.0 |
40.0 |
¡C |
Radiation Monitor High Sensitivity |
|
|
|
|
|
|
|
Radiation Monitor Med. Sensitivity |
|
|
|
|
|
|
|
Radiation Monitor Low Sensitivity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power |
5.3 |
5.7 |
6.60 |
7.2 |
7.6 |
watts |
|