Telemetry Point Low Low Nominal High High Units Comments
+5V Digital 4.8 4.9 4.998 5.1 5.2 V
+5V Analog 4.8 4.9 4.998 5.1 5.2 V
-5V Analog -5.2 -5.1 -4.988 -4.9 -4.8 V
Detector 1 Bias Current     0.007 0.25 0.50 uA
Detector 3 Bias Current     0.007 0.25 0.50 uA
Detector 5 Bias Current     0.036 0.25 0.50 uA
Detector 2 Bias Current     0.21 1.25 2.50 uA
Detector 4 Bias Current     0.20 1.25 2.50 uA
Detector 6 Bias Current     0.16 1.25 2.50 uA
Thin Detector Bias Voltage Monitor 1.0 2.0 2.5 3.0 4.0 V HV Bias Off
Thin Detector Bias Voltage Monitor 65.0 70.0 74.2 80.0 85.0 V HV Bias On
Thick Detector Bias Voltage Monitor 1.0 2.0 2.5 3.0 4.0 V HV Bias Off
Thick Detector Bias Voltage Monitor 205.0 210.0 217.5 225.0 230.0 V HV Bias On
Electrical Cal Amplitude Monitor          
Thin Detector LLD Voltage Monitor          
Thick Detector LLD Voltage Monitor          
Telescope Temperature -40.0 -30.0 0.0 25.0 40.0 íC
Analog Board Temperature -40.0 -30.0 2.8 30.0 45.0 íC
Digital Board Temperature -40.0 -30.0 4.2 40.0 55.0 íC
Power Supply Temperature -40.0 -30.0 4.9 35.0 50.0 íC
Bulkhead Reference Temperature -40.0 -30.0 0.0 25.0 40.0 íC
Radiation Monitor High Sensitivity          
Radiation Monitor Med. Sensitivity          
Radiation Monitor Low Sensitivity          
         
Power 5.3 5.7 6.60 7.2 7.6 watts



Internal Cal Low = 128 Mean Sigma
D1 Science 214.6 0.9
D2 Science 214.6 1.2
D3 Science 208.5 1.3
D4 Science 212.0 0.9
D5 Science 214.6 1.1
D6 Science 220.5 1.7